Sensitivity of microwave radiometers with square - law and linear detectors

Authors

  • Bronisław Stec Military University of Technology in Warsaw image/svg+xml
  • Andrzej Dobrowolski Military University of Technology in Warsaw image/svg+xml
  • Waldemar Susek Military University of Technology in Warsaw image/svg+xml

DOI:

https://doi.org/10.26636/jtit.2004.1.222

Keywords:

microwave thermograph, radiometer, thermal radiation, sensitivity

Abstract

Stochastic analysis of modulation microwave radiometers with square - law and linear detectors is presented in the paper. Assuming ideal detector characteristics it is shown that in typical applications, i.e., in very low power measurements, a type of detector used is of no influence on total radiometer sensitivity. Other aspects of use of a particular detector are also presented.

Downloads

Download data is not yet available.

References

[1] J. S. Bendat and A. G. Piersol, Random Data: Analysis and Measurement Procedures. New York: Wiley Interscience, 1971.
View in Google Scholar

[2] I. S. Gonorowski, Radiomechaniceskie cepi i signaly. Moskwa: Radio i svjaz, 1986 (in Russian).
View in Google Scholar

[3] B. Stec, "Microwave thermography: methods and equipment", in Proc. 11th Int. Conf. Microw., Radar Wirel. Commun. MIKON'96, Worksh., Warsaw, Poland, 1996, pp. 97-114.
View in Google Scholar

[4] M. E. Tiuri, "Radio astronomy receivers", IEEE Trans. Antenn. Propag., vol. 12, pp. 930-938, 1964.
View in Google Scholar

[5] D. F. Wait, "The sensitivity of the Dicke radiometer", J. Res. Natl. Bur. Stand. - C. Eng. Instrum., vol. 71C, no. 2, 1967.
View in Google Scholar

Downloads

Submitted

2023-04-08

Published

2004-03-30

Issue

Section

ARTICLES FROM THIS ISSUE

How to Cite

[1]
B. Stec, A. Dobrowolski, and W. Susek, “Sensitivity of microwave radiometers with square - law and linear detectors”, JTIT, vol. 15, no. 1, pp. 112–116, Mar. 2004, doi: 10.26636/jtit.2004.1.222.

Most read articles by the same author(s)